File size: 126 MBLoopCAD is the premiere software for the fast creation of professional quality circuit layout drawings for radiant heating systems. The all-new LoopCAD 2014 offers advanced design features including integrated heating and cooling load calculations, detailed hydronic calculations, snowmelt design, 3D CAD views, and compatibility with OEM design methods and materials. And now the MJ8 Edition provides ACCA-Approved Manual J (8th Edition) calculations for residential heating and cooling loads. LoopCAD is the easiest, most powerful radiant heating design tool available.
LoopCAD is available in three different editions to better match your needs. The available OEM Add-ons work seamlessly with all editions of LoopCAD. For a list of functionality and new features in each edition.
Standard Edition
Floorplan drawing and importing (PDF, AutoCAD, JPG)
Automated circuit (loop) generation.
Freehand circuit (loop) drawing.
Hydronic calculations based on manual input of heat loads (no automated heat loss calculations)
3D drawing views.
OEM Add‐ons for detailed materials lists/quotations.
Professional Edition - all features in Standard Edition, plus
Automated heat loss calculations as you draw.
ASHRAE and CSA residential heat loss calculations.
MJ8 Edition - all features in Professional Edition, plus
ACCA‐Approved Manual J (8th Edition) residential heating and cooling load calculations.
System RequirementsOperating System: Microsoft Windows 11, 10, 8, or 7 (SP1) with Internet Explorer 9 or higher, and with Microsoft .NET Framework 4.7.2
Processor: 2.0 GHz or higher recommended
RAM: 4 GB minimum, 8 GB or more recommended
Disk Space: 400 MB (Microsoft .NET Framework may require up to 4.5 GB)
Video: SVGA or higher (recommend resolution of 1920 x 1080 or higher). Support for DirectX 11 or OpenGL 2.0 (recommend minimum of 1 GB Video Memory)
Mouse: External mouse with scroll wheel (built-in mouse pads are not recommended)
Screen :What's New
Version 23.0.0080 (5/2/2023)
Tuesday, May 2, 2023
New and Enhanced Features
New dialog for setting the scale for imported drawings will help reduce unit errors.
The Grid Settings can now be set per floorplan, including the spacing, color, intensity and major line display. These settings are now saved in the project file as well.
Improved conversion of DWG background to images.
Glycol mixtures now selectable in increments of 5%.
New Custom Table for Snow Melt panel data.
Tube Depth can be shown on Custom Table for rooms and snow melt areas.
Circuit colors can be shown in the circuit table.
More options for repeating the last command using the Enter key shortcut.
New User Logo option can be used for designer credentials or stamp.
Changes specific to the CSA F280-12 calculation method
Added external shading option for windows.
Added option for ventilation that is exhaust/supply only.
For reporting requirements the Front Door can now be specified.
Added a building rotation analysis view.
Other minor changes for future CSA verification/validation.
Added CSA Summary Sheet report for CSA F280-12 reporting requirements (Annex D).
The new User Logo is automatically applied to the "Designer Logo/Certification" box on the CSA Summary Sheet report.
New CSA F280 Details View provides detailed listing of input data and calculation results.
Fixes
Fixed calculation issues when internal rooms had zero load.
Improved handling of rooms with very low heat loads.
Fix issue when using "Apply To All" on Radiant Settings step.
Fixed issue where some walls would not show in 3D view.
Fixed MJ8 Report format issue can if the user entered notes were too long.
Fixed issue with Redo command.
Fixed memory leak.
Fixed issue selecting windows in 3D view.
Fixed issue when copying a Circuit Area object that contains a manifold.
Improved the equalization of lengths when generating multiple counterflow serpentine circuits.
Improved sorting of rooms of several reports.
HOMEPAGE
https://www.avenir-online.com/AvenirWeb/LoopCAD/LoopCADHome.aspx
Buy Premium Account From My Download Links & Get Fastest Speed.